PLC Libraries for PC based systems · 0 次阅读

E_DMXLampOnMode

TYPE E_DMXLampOnMode :
(
  eDMXLampOnModeOff    := 0,   (* Lamp stays off until directly instructed to strike *)
  eDMXLampOnModeDMX    := 1,   (* Lamp strikes upon receiving a DMX512 signal *)
  eDMXLampOnModeOn     := 2,   (* Lamp strikes automatically at power-up *)
  eDMXLampOnModeAfterCal   := 3    (* Lamp strikes after calibration or homing procedure *)
);
END_TYPE