TE5960 | Autotuning · 0 次阅读

Evaluation values

After successful tuning, the parameters to be adopted can be selected here and adopted for the download or reset.

Evaluation values 1:
  • Commit: Confirms the application of the proposed controller parameters.
  • Undo: Resets the controller parameters to the default settings.
  • Suggested Position control Kv: Suggested value for the gain factor of the position controller.
  • Suggested Position control Kp: Suggested value for the gain factor of the speed controller.
  • Suggested Position control Tn: Suggested value for the integration time constant of the speed controller.
  • Suggested load inertia/mass: Suggested load inertia / total mass of the system.
  • Filter setting: Selection of suggested filters. Depending on the filter type, the corresponding parameters are displayed:
    • Filter type: Type of filter to be implemented.
    • Frequency: Frequency point in Hertz for the current command value filter.
    • Bandwidth: Bandwidth of the filter specified in Hertz.
    • Depth: Depth of the filter in decibels.