Infosys在阅读器中打开 / AI 翻译

TF5xxx - Motion · 0 次阅读

ID 294511

KPS: Ballast switch energized for too long PMx.

Description

The energy of the braked axis exceeded the limit.

Response

Class

7

Motion stop.

All active commands inhibited.

Solution

Class

6

Check power module ballast resistor and exchange if necessary.

Set braking ramp less steep.

Error type

11, Error message from position controller.