Infosys在阅读器中打开 / AI 翻译

TF5xxx - Motion · 0 次阅读

ID 120474

Maximum number of areas exceeded, area is not saved.

Description

The maximum number of stored areas is limited. This limit was exceeded. The limit value is defined by a constant in the CNC. If you need to have a greater number of areas stored, contact your controller manufacturer.

For this reason, the assigned area could not be saved.

See also [FCT-C14].

Response

Class

2

Abort NC program processing.

Solution

Class

6

Check and modify the NC program; clear the areas not required using the command
#CONTROL AREA CLEAR[ID xx]

Parameter

%1:

Identification number [-]

Area ID

%2:

Limit value [-]

Maximum number of defined areas.

%3:

Current value [-]

Number of defined areas.

Error type

1, Error message from NC program.