Infosys在阅读器中打开 / AI 翻译

TF5xxx - Motion · 0 次阅读

ID 22303

Kinematic does not support programming of IS without IT.

Description

The currently active kinematic was programmed with Status (IS) without the use of Turn (IT).

However, when Status&Turn is used, the kinematic must be programmed with the two values.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify the NC program.
Specify the associated Turn value (IT) or program without Status&Turn

Error type

1, Error message from NC program.