1. EP7047-1032 - Stepper motor box with incremental encoder
  2. Commissioning and configuration
  3. Setting the operating mode
  4. Operating modes
  5. "Ext. Velocity mode" operating mode

"Ext. Velocity mode" operating mode

Properties

Parameter

Index
(hex)

Name

Description

Unit

Data type

Default value

8010:03

Nominal voltage

The DC link voltage UP

10 mV

UINT

5000dec

8010:07

Encoder increments (4-fold)

Number of encoder increments per revolution with 4-fold evaluation.
Usually this is the resolution (ppr) of the encoder multiplied by 4.

-

UINT

4096dec

8011:01

Kp factor (curr.)

Proportional component of the current controller

 

UINT

150dec

8011:02

Ki factor (curr.)

Integral component of the current controller

 

UINT

10dec

8014:03

Kp factor (velo.)

Proportional component of the velocity controller.

0.1 mA / (rad/s)

UDINT

50dec

8014:04

Tn (velo.)

Time constant Tn of the velocity controller.

0.01 ms

UINT

50000dec