PS3031-4810-0001 | Power supply 48 V DC, 10 A, 3 phase · 0 次阅读

Charging batteries

The power supply can be used to charge lead-acid or maintenance-free batteries. (Four 12 V batteries in series).

Instructions for charging batteries:

  • Adjust the output voltage, measured at no load and at the battery end of the cable, very precisely to the end-of-charge voltage.

End-of-charge voltage

55.0 V

54.3 V

53.6 V

Battery temperature

20°C

30°C

40°C

  • Use a 15 A or 16 A circuit breaker or a blocking diode between the power supply and the battery.
  • Make sure that the output current of the power supply is below the permissible charging current of the battery.
  • Only use matched batteries when connecting 12 V types in series.
  • The return current to the power supply (battery discharge current) is typically 14 mA when the power supply is switched off (except when using a blocking diode).