2 | Primary fuse protection For the recommended power supply: 3-pole 16 A circuit breaker with B characteristic, Siemens 5SY4316-61) |
3 | Contactor switch-off Primary-side contactor switch-off2), Siemens 3RT2016-2BB421) and Siemens 3RT2916-1CB001) |
4 | Grounding Control cabinet grounding |
6 | Power supply 3-phase 48 V power supply with sufficient power according to the number of connected modules, Beckhoff PS3011-4820-00001) Direct link or Beckhoff PS3031-4820-00001) Direct link |
7 | Buffer module (optional) 48 V buffer module, Beckhoff PS9031-4820-00011) Direct link |
8, 9 | Braking resistor Brake chopper terminal, Beckhoff EL95761) Direct link with external braking resistor, Beckhoff ZB81101) Direct link |
12 | Fuse protection for parallel connection of the power supplies 32 A circuit breaker with B characteristic, Siemens 5SY4132-61) |
13 | Secondary fuse protection to the brake chopper terminal 4 A circuit breaker with C characteristic, Siemens 5SY4104-71) |
14 | Secondary fuse protection for the XTS 16 A circuit breaker with B characteristic, Siemens 5SY4116-61) |
16, 17 | Contactor switch-off 2-channel, secondary-side contactor switch-off2), Siemens 3RT2526-2BB401) and Siemens 3RT2926-1ER001) |
18 | XTS motor module Module with infeed AT20x1-02501), AT2x02-0xxx1) or AT2026-02501) |