1. KL3356, KS3356 - Accurate Terminals for Resistance Bridge
  2. Mounting and wiring
  3. Connection
  4. Connection

Connection

WARNING
Risk of injury through electric shock and damage to the device!

Bring the Bus Terminals system into a safe, de-energized state before starting mounting, disassembly or wiring of the Bus Terminals!

Connection 1:
Connection

Terminal point

No.

Connection for

+UD

1

Measuring signal

-UD

2

Measuring signal

-UV

3

Supply voltage, 0 V (from power contact)

Shield

4

PE contact

+Uref

5

Reference signal

+Uref

6

Reference signal

+UV

7

Supply voltage, 5 to 12 V (from power contact)

Shield

8

PE contact