Ramp time at feed hold (P-AXIS-00360)

The ramp time during active feed hold for manual operation is defined with this parameter.

Variable name

Type

Permissible range

Axis type

Dimension

tr_feedh

UNS32

P-AXIS-00201 < tr_feedh < MAX(UNS32)

T, R

µs

Ramp time at feed hold (P-AXIS-00360) 1:

P-AXIS-00259and P-AXIS-00360 are used only, if channel parameter P-CHAN-00097removed link: P-CHAN-00097is set to 1.