Infosys在阅读器中打开 / AI 翻译

TF5xxx - Motion · 0 次阅读

ID 14345

Feed rate is not defined or incorrect.

Description

No or an invalid feed rate (<=0) for machining or plunging is defined.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Check parameter setting and correct the input parameters for the feed rate.

Parameter

%1:

Error value

Affected input parameter @P__.

Error type

1, Error message from the NC program