1. AX5000 | Diagnostic Messages - Version 3.7
  2. Device Diagnostics
  3. F326, Additional position deviation monitoring

F326, Additional position deviation monitoring

The position deviation is outside the range of stable operation.

Can be switched off in P-0-0551.

 

Diagnostic Code (Hex.)

Diagnostic Code (Dez.)

F326

62246

Class

Type

Error

Runtime error

Standard Reaction

Reset

Nc handling

Execute Reset-Command (S-0-0099).