Infosys在阅读器中打开 / AI 翻译

ED336x-0x00 | EtherCAT Terminals, 2-channel analog input, measuring bridge, full bridge, 24 bit, push-in · 0 次阅读

Output data

Index 7000 AI Outputs UBridge Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default value

7000:0

AI Outputs UBridge Ch.1

Maximum subindex

UINT8

RO

0x06 (6dec)

7000:03

Input Freeze

The measurements are no longer passed on to the filter.

BOOLEAN

RO

0x00 (0dec)

7000:04

Tare

Rising edge starts the determination of the tare value.

BOOLEAN

RO

0x00 (0dec)

7000:05

Peak hold reset

Rising edge resets the peak hold objects

BOOLEAN

RO

0x00 (0dec)

7000:06

Disable Tare

The tare value is not taken into account.

BOOLEAN

RO

0x00 (0dec)

Index 7010 AI Outputs USense Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default value

7010:0

AI Outputs USense Ch.1

Maximum subindex

UINT8

RO

0x06 (6dec)

7010:03

Input Freeze

The measurements are no longer passed on to the filter.

BOOLEAN

RO

0x00 (0dec)

7010:04

Tare

Rising edge starts the determination of the tare value.

BOOLEAN

RO

0x00 (0dec)

7010:05

Peak hold reset

Rising edge resets the peak hold objects

BOOLEAN

RO

0x00 (0dec)

7010:06

Disable Tare

The tare value is not taken into account.

BOOLEAN

RO

0x00 (0dec)

Index 7030 RMB Sensor Outputs Ch.1

Index (hex)

Name

Meaning

Data Type

Flags

Default value

7030:0

RMB Sensor Outputs Ch.1

Maximum subindex

UINT8

RO

0x06 (6dec)

7030:03

Input Freeze

The measurements are no longer passed on to the filter.

BOOLEAN

RO

0x00 (0dec)

7030:04

Tare

Rising edge starts the determination of the tare value.

BOOLEAN

RO

0x00 (0dec)

7030:05

Peak hold reset

Rising edge resets the peak hold objects

BOOLEAN

RO

0x00 (0dec)

7030:06

Disable Tare

The tare value is not taken into account.

BOOLEAN

RO

0x00 (0dec)