Infosys在阅读器中打开 / AI 翻译

TF5xxx - Motion · 0 次阅读

ID 294016

Heat sink temperature.

Description

Thermostatic switch on the heat sinks of the servo output stage signals that the temperature of the output stage transistors is too high.

Response

Class

7

Contour-accurate stop.

All active commands inhibited.

Solution

Class

6

Rectify cause of the overheating (e.g. reduce the load).

Error type

11, Error message from position controller.