Infosys在阅读器中打开 / AI 翻译

TF5xxx - Motion · 0 次阅读

PLC parameters

Diagnosis upload

Description

While the CNC is running, the PLC can command an upload of diagnosis data using this control unit.

The control unit is enabled by enable_w = TRUE.

Data type

MC_CONTROL_BOOL_UNIT, see description of Control unit

Access

PLC reads request_r + state_r and writes command_w + enable_w

ST path

gpPform^.diagnosis_upload

Commanded, requested and return values

ST element

.command_w

.request_r

.state_r

Data type

BOOL

Value range

[TRUE = diagnosis upload activated,
FALSE = diagnosis upload off]

Redirection

ST element

.enable_w

Special feature

Note:

The data item command_w must remain at TRUE until state_r reverts to FALSE. Otherwise, the data is not complete since the diagnosis data upload is aborted.

Diagnosis upload state

Description

State value for a diagnosis upload.

 

If the diagnosis file cannot be opened, state 2 is retained and is reset in the next successful diagnosis upload.

For more information on diagnosis upload, see Diagnose-Upload [FCT-M9// Diagnosis upload]

ST path

gpPform^.diagnosis_upload_state

Data type

UDINT

Value range

Value

Constant

0

HLI_DIAG_STATE_IDLE: Basic state, diagnosis upload not active

1

HLI_DIAG_STATE_ACTIVE: Diagnosis upload active

2

HLI_DIAG_STATE_FILE_ERROR: File cannot be opened

3

HLI_DIAG_STATE_WAIT_END_ACK: Wait for acknowledgement of the diagnosis upload from the PLC

Access

PLC is reading

Note

Available as of CNC Builds V2.11.2844, V3.1.3081.4 or V3.1.3110.