TF5xxx - Motion · 0 次阅读

ID 70115

Axis machine data for D/A interface not permissible.

Description

Configuration data to access the digital/analogue interface invalid.

Response

Class

3

Job processing aborted.

Solution

Class

7

Check configuration settings in axis machine data record.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of axis affected.

Error type

-