ED336x-0x00 | EtherCAT Terminals, 2-channel analog input, measuring bridge, full bridge, 24 bit, push-in · 0 次阅读

Interface

The interface setting is fundamental for operation as an electrical measurement input.
Setting: CoE Index 0x80nD:11 "Input Interface"

Different measuring ranges are available depending on the channel:

Bridge voltageUBridge (for n=0 (Ch. 1), n=4 (Ch. 2))

  • None
  • ±20 mV
  • ±75 mV
  • ±4 V

Reference voltageUSense (for n=1 (Ch. 1), n=5 (Ch. 2))

  • None
  • ±5 V
  • ±10 V
  • ±12 V

If the interface is set to "None", the corresponding channel is disabled.

Note: When the interface is changed, the following CoE parameters of UserScale, Range Error, Limit 1/2 are reset to the default setting.

The intermediate value after this functional unit can be viewed in index 0x90n0:03 "Value after interface".