Infosys在阅读器中打开 / AI 翻译

KM3701, KM3702, KM3712 | Pressure Measuring Modules · 0 次阅读

KM3701 - Process image

The KM3701 terminal module is represented in the process image with a maximum of 3 bytes of input data and 3 bytes of output data. These are organized as follows:

Format

Input data

Output data

Byte

SB

CB

Word

DataIN

DataOUT

Key

SB: Status byte
CB: Control byte

DataIN: Input data word
DataOUT: Output data word

  • The meaning of the control and status bytes is explained in Control and status bytes.
  • In process data mode, the analog value is transferred in the input data word DataIN. The output data word DataOUT is not used.

Representation of the analog values

The terminal module displays the analog input values as follows:

KM3701

Differential pressure

Decimal

Hexadecimal

-100 hPa

-1000

0xFC18

0 hPa

0

0x0000

+100 hPa

+1000

0x03E8

KM3701-0340

Differential pressure

Decimal

Hexadecimal

-340 hPa

-3400

0xF2B8

0 hPa

0

0x0000

+340 hPa

+3400

0x0D48