PS9771-2440-0000 | DC/DC Converter 475-750 V / 24 V, 40 A, 960 W · 0 次阅读

Charging batteries

The power supply can be used to charge lead-acid or maintenance free batteries. (Two 12V batteries in series)

Instructions for charging batteries:

  • Set the output voltage (measured at no load and at the end of the battery cable) very precisely to the end-of-charge voltage.

End-of-charge voltage

27.8V

27.5V

27.15V

26.8V

Battery temperature

10°C

20°C

30°C

40°C

  • Use a 50A or 63A circuit breaker (or blocking diode) between the power supply and the battery.
  • Ensure that the output current of the power supply is below the allowed charging current of the battery.
  • Use only matched batteries when putting 12V types in series.
  • The return current to the power supply (battery discharge current) is typ. 18mA when the power supply is switched off (except in case a blocking diode is utilized).