Infosys在阅读器中打开 / AI 翻译

TF5xxx - Motion · 0 次阅读

ID 20162

Unknown H-function, since not defined in the channel parameters.

Description

The programmed H function is not configured in the channel parameter list P-CHAN-00027 or exceeds a maximum value and is therefore not known in the NC channel.

Response

Class

2

Abort NC program processing.

Solution

Class

3

Define H function in the channel parameter list P-CHAN-00027.

Parameter

%1:

Error value [-]

Number of the unknown H function

Error type

1, Error message from NC program.