EL515x | Incremental Encoder Interface · 0 次阅读

Period calculation

  • This calculation is carried out free-running in the slave without reference to the distributed clocks system. It is therefore independent of the DC mode.
  • During each cycle the interval between two positive edges of input A is counted.
  • Depending on the setting, periods of up to 1.6 s or 3.2 s (only for EL5151) in length are measurable.