Interfaces

The user can operate the linear slave axis via the System Manager or PLC blocks. Furthermore, a cyclic NC-PLC interface is available (in the System Manager or via the PLC) that contains the axis process image and enables access to various variables.

System Manager

The System Manager offers access to the complete slave axis functionality

  • Coupling with declaration of the master axis and setting of the coupling factor
  • Changing the coupling factor
  • Uncoupling

PLC Blocks

The SPS Library offers access to the complete slave axis functionality

  • Coupling with declaration of the master axis and setting of the coupling factor
  • Changing the coupling factor
  • Uncoupling

NC-PLC-Interface

The cyclic NC-PLC axis interface contains the axis process image and particularly access to the coupling information (coupling flag).