Infosys在阅读器中打开 / AI 翻译

EPxxxx | Industrial housing · 0 次阅读

Overcurrent protection for sum currents

EP9224-0037 determines two types of sum currents:

  • Sum current for each individual EtherCAT P port (calculated)
    US + UP
  • Sum current for all EtherCAT P ports (measured)
    ∑ (US + UP)

The overcurrent protection for sum currents is disabled in the factory settings. It can be individually activated and parameterized for each sum current:

Sum current

CoE indices

Activation

"Enable Sum Current Limitation"

Nominal current

"Nominal Sum Current"

Tripping characteristic

"Sum Current Characteristic"

X52: US + UP

8000:04

8000:14

8000:11

X53: US + UP

8010:04

8010:14

8010:11

X54: US + UP

8020:04

8020:14

8020:11

X55: US + UP

8030:04

8030:14

8030:11

∑ (US + UP)

(Sum of all output currents)

F80E:02

F80E:12

F80E:13