TX1270 | TwinCAT CNC · 0 次阅读

Remaining deviation for non linear following error monitoring (P-AXIS-00166)

The parameter defines the remaining deviation for non linear following error monitoring. This parameter must be determined empirically.

Variable name

Type

Permissible range

Axis type

Dimension

slep_abw

UNS32

0 < slep_abw < 1024

T, R

----